UPS MTI 25kVA - 200kVA Tescom
Tikweld Welding Supplies and Services is a distributor of Tescom Power Products in Nigeria. The UPS MTI 25kVA - 200kVA Tescom Rack Mounted Modular UPS is scalable, hot-swappable, online double conversion and the power capacity is from 25 to 200kVA/kW.
Our UPS MTI 25kVA - 200kVA Tescom is the ideal choice for modern data center and with the latest IGBT three-level and full DSP control technology, the new RM series delivers the best combination of reliability and flexibility.
Application of UPS MTI 25kVA - 200kVA Tescom
IDC (Internet Data Center), network servers and workstation, control system, communication system, office, PC etc
Specification of UPS MTI 25kVA - 200kVA Tescom
INPUT
|
Dual input
|
Optional
|
Standard
|
Phase
|
3 Phase + Neutral + Ground, 380V/400V/415V(line-line)
|
Input voltage range
|
304~478Vac (line-line),full load; 228V~304Vac (line-line),load decreases linearly according to the min phase voltage
|
Rate frequency
|
50/60Hz
|
Input frequency range
|
40Hz~70Hz
|
Input power factor
|
> 3% (100% Linear load)
|
BYPASS
|
Rate voltage
|
380V/400V/415VAC (line-line)
|
Rate frequency
|
50/60Hz
|
Input voltage range
|
Settable, -40%~+25%
|
Bypass frequency range
|
Settable, ±1Hz, ±3Hz, ±5Hz
|
Bypass overload
|
110% long term operation; 125% for 5 mins ;150% for 1 min; >150% for 1s
|
OUTPUT
|
Rate voltage
|
380/400/415VAC (line-line)
|
Voltage regulation
|
±1(0~100% linear load)
|
Rate frequency
|
50/60Hz
|
Frequency precision
|
0.1%
|
Output power factor
|
1
|
Output THDu
|
<1% , Linear load; <6%, Non-linear load
|
Crest factor
|
3:1
|
Inverter overload
|
110% for 1 hour; 125% for 10 mins ;150% for 1 min; >150% for 200 ms
|
BATTERY
|
Voltage
|
±240VDC
|
Battery number
|
40pcs (Settable: even number from 32 to 44)
|
Voltage precision
|
±1%
|
Charge power
|
up to 20% * Output active power Standard
|
Battery cold start
|
Standard
|
SYSTEM
|
Efficiency
|
AC mode
|
96.0%
|
ECO mode
|
98.0%
|
DC mode
|
96.0%
|
Display
|
7.0" color touch screen LCD + LED + keyboard
|
IP class
|
IP20
|
Interface
|
RS232, RS485, Programmable Dry Contact
|
Option
|
PDU for RM150/25C,SNMP Card, Parallel kit,SPD, LBS
|
Temperature
|
Operation: 0~ 40 ℃ Storge: -40 ~70 ℃ 0 ~
|
Relative humidity
|
0 ~95% Non-condensing
|
Altitude
|
<1000m. Within 1000m to 2000m, power derate 1% for every 100m rise
|
Noise (1 Meter)
|
65dB @ 100% load, 62dB @ 45% load
|
Applicable standards
|
Safety: IEC/EN 62040-1-1 EMC: IEC/EN 62040-2 Performance: IEC/EN 62040-3
|
PHYSICAL
|
Weight (kg)
|
Cabinet
|
140
|
160
|
Power module
|
18
|
Dimensin WxDxH (mm)
|
Cabinet
|
482x916x931
|
482x916x1550
|
Power module
|
436x677x85
|
Contact us today for more info.