ARI

Contec Electrocardiograph Touch Screen ECG1200G

(2 reviews) Write a Review
SKU:
Contec ECG1200G
MPN:
Contec ECG1200G
Availability:
available
₦1,600,000.00

Description

Contec Electrocardiograph Touch Screen ECG1200G 

Tikweld Supplies and services Nigeria is the distributor of Patient Trolley and Medical Equipment in Nigeria. The Contec Electrocardiograph Touch Screen ECG1200G forms  an increasingly important element of a healthcare professional’s role.

Our Contec Electrocardiograph Touch Screen ECG1200G  is an electrocardiograph can collect 12-lead ECG signal simultaneously and print ECG waveform with thermal printing system. It features in, recording and displaying ECG waveform in AUTO/Manual mode, measuring and diagnosing ECG waveform parameters automatically, prompting for “Lead off” and “Lack of paper”, multi-language interface, AC/DC, selecting rhythm lead, printing the trend chart and histogram of P-R interval, case database management.

Function of Contec Electrocardiograph Touch Screen ECG1200G 

  • Sync collection for 12-lead ECG, adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.
  • Display of 3/6/12-lead ECG, print mode, sensitivity, paper speed and filter state, etc. on one screen, convenient for contrastively diagnosing.
  • Multiply printing modes and formats, including auto 12x1, auto 6x2+1, auto 6x2+1_H, auto 6x2, auto 6x2_H, auto 3x4+1, auto 3x4+2, rhythm 12, rhythm 10, rhythm 8, rhythm 6, manual, etc. Trend chart and histogram of P-R interval can be printed, waveform length printed can be adjusted, and with time print function, which meets different requirements.
  • Paper speed: 5mm/s, 6.25mm/s, 10mm/s, 12.5mm/s, 25mm/s, 50mm/s.

With the functions of auto-analysis and auto-diagnosis for routine ECG parameters, provide measurement results and auto-diagnosis conclusion for HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1), etc. which reduces the doctor’s burden.

  • Built-in memory stores up to 1000 cases, convenient for case review and statistic.
  • Multi-language(Turkish, French, Chinese, English, German, Kazakstan, Polish, Portuguese, Russian, Slovenian, Spanish and Ukrainian) interface and report.
  • In optimal DC state, up to 10-hour standby time, continuous print more than 3-hour, record up to 300 ECG waveform(commonly, it is 3s case), which meets the requirements of visiting a patient at home and body examination.

Performance of Contec Electrocardiograph Touch Screen ECG1200G 

  • Input mode: floating and defibrillation protection
  • Frequency response: 0.05Hz ~ 150Hz(-3dB~+0.4dB)
  • CMRR: >60dB, >100dB(add filter)
  • Time constant:≥ 3.2s
  • Patient leak current: <10µA
  • Calibration voltage: 1mV
  • Sensitivity: 2.5, 5, 10, 20, 40 mm/mV ±5%, standard sensitivity: 10mm/mV±2%
  • Noise level: ≤15µVp-p
  • Input circuit current: ≤50nA
  • Input impedance: ≥50MΩ
  • Sampling accuracy: 12-bit
  • Safety classification: class I, type CF and defibrillation-proof applied part
  • Recording mode: thermal printing system
  • Paper size: 210mm(W)×20m(L)
  • Sampling frequency: 1000Hz
  • EMG interference filter: 25Hz/35Hz (-3dB)
  • Power frequency filter: AC 50Hz/60Hz(-20dB)
  • Paper speed:
  • Auto: 25, 50mm/s, ±5%
  • Rhythm: 25, 50mm/s, ±5%
  • Manual: 5, 6.25, 10, 12.5, 25, 50mm/s, ±5%
  • Auto record: set record according to auto record format and mode, automatically switching leads, measuring and analyzing.
  • Rhythm record: set record according to rhythm record format and mode, automatically measuring and analyzing.
  • Manual record: set record according to record format, manually switching leads.
  • Measurement parameters: HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1)
  • Power supply:
  • AC: 100V~240V(50/60Hz)
  • DC: 14.8V/3500mAh rechargeable lithium battery
  • Fuse specification: two AC time lag fuse(φ5×20mm), T1.6AL250V
  • Waterproof degree: IPX0
  • Working mode: continuous working

PHYSICAL PROPERTIES OF ECG1200G DIGITAL 12 CHANNEL/LEAD , ELECTROCARDIOGRAPH TOUCH SCREEN CONTEC

  • Working environment
  • Temperature: 5℃~40℃
  • Relative humidity: 25%~95%(non-condensing)
  • Atmospheric pressure: 700hPa~1060hPa
  • Transport and storage environment
  • Temperature: -40℃~+55℃
  • Relative humidity: ≤95%
  • Atmospheric pressure: 500hPa~1060hPa
  • Dimension: 340mm(L) × 320mm(W) × 85mm(H)
  • Weigh: 3.2Kg

  Please contact us for product availability

View AllClose

2 Reviews

  • 5

    CONTEC ELECTROCARDIOGRAPH TOUCH SCREEN ECG1200G

    Posted by Amanda Ibu on 9th Jun 2022

    CONTEC ELECTROCARDIOGRAPH TOUCH SCREEN ECG1200G is the best cardiograph you can use, it stores up to 1000 cases that's why I love this machine

  • 5

    Best

    Posted by Nichole Ken on 9th Jun 2022

    very sensitive and effective machine. you know, some machine loses their sensitivity when used often but you see this, it gives me an accurate reading in my medical analysis not minding how long it has been and has also served me perfectly. thumbs up guys

View AllClose